This study compared the in vitro optical quality of a trifocal (OptiFlex Trio) intraocular lens (IOL) and an extended-depth-of-focus (EDOF) (Asqelio) IOL to predict post-cataract surgery visual acuity. Through-focus modulation transfer function (TF-MTF) was measured using an eye model with two pupil diameters: 3.0 mm and 4.5 mm (at the IOL plane)Visual acuity and range of vision were estimated from the area under the TF-MTF curve. For a 3.0 mm pupil, both IOLs predicted sustained visual acuity better than 0.2 logMAR from distance to -3.0 D (33 cm) vision. The EDOF IOL performed slightly better for distance and intermediate vision, while the trifocal IOL provided an additional 1D range, extending to near vision. Unwanted photopic side effects (halos) were analysed from pinhole image intensity. © Anita Publications. All rights reserved.
Doi: 10.54955/AJP.33.12.2024.805-814
Keywords: Cataract surgery, Intraocular lens, Multifocal lens, Extended depth of field, Modulation transfer function, Visual acuity.
Peer Review Information
Method: Single- anonymous; Screened for Plagiarism? Yes
Buy this Article in Print © Anita Publications. All rights reserve
References
- Ruiz-Mesa R, Abengózar-Vela A, Ruiz-Santos M. A comparative study of the visual outcomes between a new trifocal and an extended depth of focus intraocular lens, Eur J Ophthalmol, 28(2018)182–187.
- Liu J, Dong Y, Wang Y. Efficacy and safety of extended depth of focus intraocular lenses in cataract surgery: A systematic review and meta-Analysis, BMC Ophthalmol,19(2019)198; doi: 10.1186/s12886-019-1204-0.
- Azor J A, Vega F, Armengol J, Millan M S, Optical assessment and expected visual quality of four extended range of vision intraocular lenses, J Refract Surg, 38(2022)688–697.
- Ribeiro F, Dick H B, Kohnen T, Findl O, Nuijts R, Cochener B, Fernández J, Evidence-based functional classification of simultaneous vision intraocular lenses: seeking a global consensus by the ESCRS Functional Vision Working Group, J Cataract Refract Surg, 50(2024)794–798.
- Plaza-Puche A B, Alió J L, Mac Rae S, Zheleznyak L, Sala E, Yoon G, Correlating optical bench performance with clinical defocus curves in varifocal and trifocal intraocular lenses, J Refract Surg, 31(2015)300–307.
- Alarcon A, Canovas C, Rosen R, Weeber H, Tsai L, Hileman K, Piers P, Preclinical metrics to predict through-focus visual acuity for pseudophakic patients, Biomed Opt Express, 7(2016)1877–1888.
- Vega F, Millán M S, Garzón N, Altemir I, Poyales F, Larrosa JM. Visual acuity of pseudophakic patients predicted from in-vitro measurements of intraocular lenses with different design, Biomed Opt Express, 9(2018)4893; doi: 10.1364/BOE.9.004893.
- ISO Standard.11979-2:2024. Ophthalmic Implants – Intraocular Lenses – Part 2: Optical Properties and Test Methods. International Organization for Standardization, Geneva, Switzerland, 2024.
- The Accredited Committee Z80 for Opthamic Standards. Extended depth10000 of focus intraocular lenses. American National Standard Institute ANSI Z80.35–2018, 2019.
- Fernández J, Ribeiro F, Rocha-De-Lossada C, Rodríguez-Vallejo M. Functional classification of intraocular lenses based on defocus curves: A scoping review and cluster analysis, J Refract Surg, 40(2024)e108–e116. [email protected]
- Rampat R, Gatinel D, Multifocal and extended depth-of-focus intraocular lenses in 2020, Ophthalmol, 28(2021)64–85.
- Cerviño A, Esteve-Taboada J J, Chiu YF, Yang CH, Tseng WC, Lee W. Tolerance to decentration of biaspheric intraocular lenses with refractive phase-ring extended depth of focus and diffractive trifocal designs, Graefe’s Archive for Clinical and Experimental Ophthalmology, 262(2024)2541–2550.
- Brar S, Ganesh S, Nikhil RP, Roopashree CR. Clinical outcomes and patient satisfaction with a new diffractive-refractive trifocal intraocular lens – A 12-month prospective study, Clin Ophthalmol, 15(2021)3247–3257.
- Vega F, Alba-Bueno F, Millán M S, Energy distribution between distance and near images in apodized diffractive multifocal intraocular lenses, Invest Ophthalmol Vis Sci, 52(2011)5695–5701.
- Stern B, Gatinel D. Impact of pupil size and corneal spherical aberrations on the performance of monofocal intraocular lenses: An experimental model, Biomed Opt Express, 15(2024)6433–6448.
- Wang L, Koch D D, Hill W, Abulafia A, Pursuing perfection in intraocular lens calculations: III. Criteria for analyzing outcomes, J Cataract and Refract Surg, 43(2017)999–1002.
- Łabuz G, Yan W, Baur I D, Khoramnia R, Auffarth G U. Comparison of five presbyopia-correcting intraocular lenses: Optical-bench assessment with visual-quality simulation, J Clin Med, 12(2023)2523; doi: 10.3390/jcm12072523.
- Atchison D A, Smith G. Retinal image quality. In: Optics of the Human Eye, (Elsevier), 2000, p 194–210.
- Armengol J, Garzón N, Vega F, Altemir I, Millán M S, Equivalence of two optical quality metrics to predict the visual acuity of multifocal pseudophakic patients, Biomed Opt Express, 11(2020)2818–2829.
- Papadogiannis P, Gambra E, Łabuz G, Yan W, Martín-Becerra D, Sisó-Fuertes I, de Castro A, Barcala X, Auffarth G U, Dorronsoro C, Sawides L,. Visual simulation of intraocular lenses: from on-bench performance to computational and experimental validations, Biomed Opt Express, 15(2024)6521–6530.
- Kaya Ünsal S, Sunay E. The impact of angle lambda on patient satisfaction after Optiflex Trio trifocal intraocular lens implantation, J Ophthalmol, (2023)7911449; doi: 10.1155/2023/7911449.
- Yan W, Łabuz G, Khoramnia R, Auffarth G U, Trifocal intraocular lens selection: Predicting visual function from optical quality measurements, J Refract Surg, 39(2023)111–118.
- Fernández-Vega-Cueto L, Madrid Costa D, Alfonso Bartolozzi B, Vega F, Millán M S, Alfonso J F, Optical and clinical outcomes of an extended range of vision intraocular lens, J Refract Surg, 38(2022)168–176.
- Vega F, Garzón N, García-Montero M, Millán M S. Power profile and optical performance of two extended range of vision intraocular lens designs, J Cataract Refract Surg, 50(2024)1065–1073.